Report

Randomised Assessment of Treatment using Panel Assay of Cardiac markers - Contemporary Biomarker Evaluation (RATPAC CBE)

Authors: Collinson P, Gaze D, Thokala P, Goodacre S

Journal: Health Technology Assessment Volume: 17 Issue: 15

Publication date: April 2013

DOI: 10.3310/hta17150

Citation:

Collinson P, Gaze D, Thokala P, Goodacre S.Randomised Assessment of Treatment using Panel Assay of Cardiac markers - Contemporary Biomarker Evaluation (RATPAC CBE). Health Technol Assess 2013;17(15)


RATPAC CBE (Vol 17:15) was a sub-study of the point-of-care arm of the RATPAC trial (Vol 15:23).

Journal issues* can be purchased by completing the form.


The cost of reports varies according to number of pages and postage address. The minimum cost for a copy sent to a UK address is £30.00. We will contact you on receipt of your completed form to advise you of actual cost. If you have any queries, please contact nihredit@southampton.ac.uk.


*We regret that unfortunately we are unable to supply bound print copies of Health Technology Assessment published before issue 12:31. However, PDFs are available to print from the "Downloads" tab of the issue page.

Responses

No responses have been published. If you would like to submit a response to this publication, please do so using the form below.

Comments submitted to the NIHR Journals Library are electronic letters to the editor. They enable our readers to debate issues raised in research reports published in the Journals Library. We aim to post within 2 working days all responses that contribute substantially to the topic investigated, as determined by the Editors.

Your name and affiliations will be published with your comment.

Once published, you will not have the right to remove or edit your response. The Editors may add, remove, or edit comments at their absolute discretion.

Post your response

Surname

Forename

Middle Initial

Occupation / Job title

Affiliation / Employer

Email

Address

Other authors

For example, if you are responding as a team or group. Please ensure you include full names and separate these using commas

Statement of competing interests

We believe that readers should be aware of any competing interests (conflicts of interest).

The International Committee of Medical Journal Editors (ICMJE) define competing interests as including: financial relationships with industry (for example through employment, consultancies, stock, ownership, honoraria, and expert testimony), either directly or through immediate family; personal relationships; academic competition; and intellectual passion.

If yes, provide details below:

Enter response title

Enter response message

Enter CAPTCHA

Security key

Regenerate security key

By submitting your response, you are stating that you agree to the terms & conditions

  • Abstract

Abstract

Objectives

To test the diagnostic accuracy for detecting an acute myocardial infarction (AMI) using highly sensitive troponin assays and a range of new cardiac biomarkers of plaque destabilisation, myocardial ischaemia and necrosis; to test the prognostic accuracy for detecting adverse cardiac events using highly sensitive troponin assays and this range of new cardiac biomarkers; and to estimate the cost-effectiveness of using highly sensitive troponin assays or this range of new cardiac biomarkers instead of an admission and 10- to 12-hour troponin measurement.

Design

Substudy of the point-of-care arm of the RATPAC (Randomised Assessment of Treatment using Panel Assay of Cardiac markers) trial.

Setting

The emergency departments of six hospitals.

Participants

Prospective admissions with chest pain and a non-diagnostic electrocardiogram randomised to point-of-care assessment or conventional management.

Interventions

Blood samples taken on admission and 90 minutes from admission for measurement of cardiac markers [cardiac troponin I (cTnI), myoglobin and creatine kinase MB isoenzyme (CK-MB)] by point-of-care testing. An additional blood sample was taken at admission and 90 minutes from admission for analysis of high-sensitivity cTnI (two methods) and cardiac troponin T (cTnT), myoglobin, heart-type fatty acid-binding protein (H-FABP), copeptin and B-type natriuretic peptide (NTproBNP).

Main outcome measures

1. Diagnostic accuracy compared with the universal definition of myocardial infarction utilising laboratory measurements of cardiac troponin performed at the participating sites together with measurements performed in a core laboratory. 2. Ability of biomarker measurements to predict major adverse cardiac events (death, non-fatal AMI, emergency revascularisation or hospitalisation for myocardial ischaemia) at 3 months' follow-up. 3. Comparison of incremental cost per quality-adjusted life-year (QALY) of different biomarker measurement strategies for the diagnosis of myocardial infarction.

Results

Samples were available from 850 out of 1132 patients enrolled in the study. Measurement of admission myoglobin [area under the curve (AUC) 0.76] and CK-MB (AUC 0.84) was diagnostically inferior and did not add to the diagnostic efficiency of cTnI (AUC 0.90-0.94) or cTnT (AUC 0.92) measurement on admission. Simultaneous measurement of H-FABP and cTnT or cTnI did improve admission diagnostic sensitivity to 0.78-0.92, but only to the same level as that achieved with troponin measured on admission and at 90 minutes from admission (0.78-0.95). Copeptin (AUC 0.62) and NTproBNP (AUC 0.85) measured on admission were not useful as diagnostic markers. As a prognostic marker, troponin measured on admission using a high-sensitivity assay (AUC 0.73-0.83) was equivalent to NTproBNP measurement (AUC 0.77) on admission, but superior to copeptin measurement (AUC 0.58). From modelling, 10-hour troponin measurement is likely to be cost-effective compared with rapid rule-out strategies only if a £30,000 per QALY threshold is used and patients can be discharged as soon as a negative result is available.

Conclusions

The measurement of high-sensitivity cardiac troponin is the best single marker in patients presenting with chest pain. Additional measurements of myoglobin or CK-MB are not clinically effective or cost-effective. The optimal timing for measurement of cardiac troponin remains to be defined. Copeptin measurement is not recommended. H-FABP requires further investigation before it can be recommended for simultaneous measurement with high-sensitivity troponin in patients with acute chest pain.

Trial registration

ISRCTN37823923.

Funding

This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 17, No. 15. See the HTA programme website for further project information.

Publication updates

If you would like to receive information on publications and the latest news, click below to sign up.